12kW-30kW LNG Generators

12kW-30kW LNG Generators

12kW-30kW LNG Generator is an efficient and clean energy power generation equipment developed specifically for small and medium-sized industrial sites, commercial complexes, data centers, hospitals, hotels, new energy supporting facilities, and other scenarios
Send Inquiry
Chat Now
Description

This series of LNG generators adopts high-quality LNG specific engines, efficient permanent magnet synchronous generators, integrated LNG supply systems, and intelligent control panels. They are compatible with liquefied natural gas (LNG) that meets the GB 17820-2018 standard, with a methane content of ≥ 95%, fully complying with international authoritative standards and industry norms. They have the advantages of high power generation efficiency, emission standards, stable operation, moderate noise, convenient storage, safety and reliability, perfectly meeting the daily power supply, emergency power supply and continuous operation needs of small and medium-sized industrial and commercial places.

 

Product Parameter

 

Model

LNG-12kW (Standard Edition)

LNG-15kW (Enhanced Edition)

LNG-20kW (industrial version)

rated power

12kW

15kW

20kW

maximum power

13.2kW

16.5kW

22kW

Adaptive fuel

Liquefied natural gas (LNG), methane content ≥ 95%

Liquefied natural gas (LNG), methane content ≥ 95%

Liquefied natural gas (LNG), methane content ≥ 95%

Voltage specifications

220V (single-phase)/380V (three-phase) optional

220V (single-phase)/380V (three-phase) optional

380V (three-phase)

frequency

50Hz/60Hz switching, stability ± 0.5%

50Hz/60Hz switching, stability ± 0.5%

50Hz/60Hz switching, stability ± 0.5%

LNG consumption (full load)

1.8~2.0m ³/h (gaseous equivalent)

2.2~2.5m ³/h (gaseous equivalent)

3.0~3.2m ³/h (gaseous equivalent)

Startup method

Electric start, supports manual/automatic start stop

Electric start, supports manual/automatic start stop

Electric start, supports automatic start stop and remote start

Continuous running time

24-hour uninterrupted (stable LNG supply)

24-hour uninterrupted (stable LNG supply)

24/7 uninterrupted (operating for over 8000 hours per year)

Operating noise (1 meter away)

≤68dB

≤70dB

≤ 72dB (equipped with a soundproof cover)

Body dimensions (length x width x height)

160×80×100cm

170×85×105cm

180×90×110cm

Body weight (excluding LNG storage tank)

280kg

320kg

380kg

Adapt to tank specifications

50L~100L small LNG storage tank

100L~200L small LNG storage tank

200L~500L medium-sized LNG storage tank

Protection level

IP54 (splash proof/dust-proof/corrosion-resistant)

IP54 (splash proof/dust-proof/corrosion-resistant)

IP54 (splash proof/dust-proof/corrosion-resistant)

Applicable ambient temperature

-20℃~50℃

-20℃~50℃

-25℃~55℃

power generation efficiency

≥38%

≥38.5%

≥39%

Exhaust standard

Compliant with Euro 6/National VI emission standards

Compliant with Euro 6/National VI emission standards

Compliant with Euro 6/National VI emission standards

Note: The above are standard parameters, and LNG consumption is slightly affected by fuel purity, operating load, and environmental temperature; Minor adjustments can be made based on the user's electricity demand, installation space, and LNG supply conditions, subject to the actual product.

 

Product feature and application

Clean and environmentally friendly, low-carbon emissions

Using liquefied natural gas (LNG) as fuel, it burns fully without black smoke or carbon deposits, and its emissions fully comply with Euro 6/National VI emission standards. The emissions of carbon monoxide, nitrogen oxides, and particulate matter are much lower than those of fuel generators, and carbon emissions are reduced by more than 70% compared to fuel generators. It truly achieves clean power generation, adapts to industrial and commercial scenarios with strict environmental policies, and helps promote low-carbon transformation.

Efficient and energy-saving, low operation and maintenance costs

Adopting advanced LNG dedicated combustion system and efficient permanent magnet synchronous generator, the power generation efficiency is as high as 38%~39.5%, and the energy utilization rate far exceeds traditional fuel generators; The price of LNG fuel is stable, with a cost reduction of 30% to 40% compared to diesel and gasoline fuels. The equipment operates without oil pollution, with less carbon buildup, minimal engine wear, and a long maintenance cycle (every 500 hours), significantly reducing operation and maintenance costs and parts replacement costs.

High energy density, convenient storage and transportation

LNG is the liquid form of natural gas, with an energy density 625 times that of gaseous natural gas. It has a small volume and light weight, and can be stored in small and medium-sized storage tanks ranging from 50L to 1000L. It occupies a small space and is suitable for indoor and outdoor installation; The storage tank has good sealing performance, low LNG volatilization, and safe storage. It can be delivered in bulk through dedicated transportation vehicles, solving the pain points of "pipeline dependence and inconvenient storage" for ordinary natural gas generators.

 

It can be used in various scenarios.

1. Small and medium-sized industrial sites

Suitable for small factories, workshops, production lines, small-scale breeding farms, agricultural product processing plants and other small and medium-sized industrial sites, it is recommended to use LNG-20kW industrial version or LNG-30kW flagship version. Can serve as the main power supply equipment, providing continuous and stable power for production equipment, processing machinery, lighting, office, etc; It can also be used as a backup emergency power supply equipment to cope with power outages and grid fluctuations, ensure uninterrupted production, and meet environmental protection requirements in industrial scenarios, reducing electricity consumption and operation and maintenance costs.

 

2. Commercial premises

Suitable for commercial places such as hotels, shopping malls, supermarkets, office buildings, restaurants, gas stations, etc. It is recommended to use LNG-12kW standard version or LNG-15kW enhanced version. Mainly relying on emergency backup power supply, standby when the mains power is normal, and automatically start within 10 seconds when the mains power is interrupted, to ensure the normal operation of key facilities such as elevators, cash register equipment, refrigeration and freezing equipment, lighting, air conditioning, communication equipment, etc., and avoid economic losses caused by business interruption; Some commercial places can be used as auxiliary power supply to reduce electricity bills by using off peak electricity.

 

3. Public service facilities

Suitable for public service facilities such as hospitals, schools, nursing homes, transportation hubs, communication base stations, data centers, etc., it is recommended to use LNG-20kW industrial version or LNG-30kW flagship version. As the core emergency power supply equipment, it ensures the continuous operation of key facilities such as medical equipment, teaching equipment, elevators, communication base stations, and data servers in the event of a power outage, ensuring the continuity of public services and data security; The characteristics of cleanliness and environmental protection are suitable for the green operation needs of public facilities.

 

Production details

 

1. Installation instructions
Installation needs to be carried out by a professional team to ensure compliance with safety regulations and electricity standards: ① Site selection requirements: choose a flat, ventilated, and away from fire sources, heat sources, and flammable and explosive materials. For indoor installation, ventilation openings should be reserved (with a ventilation rate of ≥ 10 times per hour), and for outdoor installation, rain and sun protection measures should be taken; ② Equipment fixation: The machine body is fixed with anchor bolts to ensure vibration free operation; ③ Gas supply connection: connect the LNG storage tank to the generator gas supply system. After the sealing test shows no leakage, adjust the pressure reducing valve and the carburetor to the standard range; ④ Circuit connection: Connect to the distribution box at the site, install circuit breakers and grounding devices, ensure proper wiring, and conduct insulation testing; ⑤ Debugging and operation: Check the oil and coolant levels, start the equipment for no-load, half load, and full load tests, confirm stable operation and normal parameters before putting it into use.

 

2. Daily operation and maintenance
① Daily inspection: Before starting, check the liquid level and pressure of the LNG storage tank, whether the gas hose leaks, whether the control panel parameters are normal, and whether the engine oil and coolant levels meet the standards; Monitor power generation, LNG consumption, and equipment temperature during operation, and immediately shut down for inspection if any abnormalities are found; ② Regular maintenance: Replace the engine oil, oil filter, and air filter every 500 hours of operation; Clean the vaporizer, pressure reducing valve, and check the seals every 1000 hours of operation; Check the engine valve clearance and spark plug every 2000 hours of operation (gasoline starter models); Fully inspect safety protection devices every six months; ③ Caution: It is strictly prohibited to operate equipment in a confined space to prevent safety risks caused by LNG leakage; LNG storage tanks should be kept away from sources of fire, avoid exposure to sunlight, and regularly check the sealing of the tanks; When not in use for a long time, close the LNG valve, empty the gas supply pipeline, and store it in a dry and ventilated place.

254001
255001
251001
252001
253001

256

257001

258001

 

Product Certification

 

The 12kW-30kW LNG Generator relies on advanced LNG power generation technology, strict quality control system, and high-quality component supply. It has passed multiple international authoritative certifications and industry certifications, with complete qualifications and guaranteed quality.

43

44

 

FAQ

 

Q: What are the advantages of LNG generators compared to fuel generators?

A: Compared to fuel generators, LNG generators have three core advantages: ① better environmental friendliness: emissions meet the National VI standard, carbon emissions are reduced by more than 70%, there is no black smoke or carbon accumulation, and they are compatible with environmental policies; ② Lower operating costs: LNG fuel prices are stable, reducing diesel costs by 30% to 40%, and the maintenance cycle is long, resulting in lower operation and maintenance costs; ③ Higher safety: LNG combustion has no risk of explosion, and after leakage, it quickly vaporizes and spreads. Its safety far exceeds that of fuel, and there is no oil pollution.

Q: Do LNG storage tanks need to be replaced regularly? Is there a safety risk during storage?

A: LNG storage tanks do not require regular replacement and can have a service life of 8-10 years under normal use. Regular (once a year) testing of the tank's sealing and pressure resistance is sufficient. The safety risk during storage is extremely low: ① The storage tank is made of specialized low-temperature pressure resistant materials with excellent sealing performance, and the LNG volatilization rate is ≤ 0.5%/day; ② Equipped with an automatic overpressure relief device, which automatically releases pressure when the pressure exceeds the standard to avoid damage to the storage tank; ③ After LNG leakage, it will quickly vaporize, with a lower density than air, and will spread upwards, making it less likely to accumulate and cause explosions. Its safety is much higher than that of liquefied gas storage tanks.

Q: Can a 20kW LNG generator meet the production electricity needs of small factories?

A: Absolutely possible! A 20kW LNG generator can meet the basic production electricity needs of small factories and workshops, and can simultaneously drive 2-3 small processing machinery (such as lathes, milling machines), lighting, office equipment, ventilation fans, and other equipment to operate (multiple high-power devices can be turned on at the same time). If the electrical load is large, multiple units can be operated in parallel (up to a maximum of 120kW), fully meeting the production power supply needs of small factories.

Q: Can the equipment start and operate normally in low temperature environments (such as -20 ℃)?

A: Can start and run normally! This series of LNG generators is suitable for a wide temperature range of -20 ℃~50 ℃ (up to -25 ℃ for 20kW/30kW models) and is equipped with a low-temperature starting auxiliary device. Even in a low-temperature environment of -25 ℃, it can be started with one click without additional heating; The LNG vaporizer adopts a low-temperature adaptation design, with stable vaporization efficiency in low-temperature environments, ensuring sufficient gas supply and no fluctuations in equipment operation.

 

Packing & Shipping

 

205001
206001

 

Hot Tags: 12kw-30kw lng generators, China 12kw-30kw lng generators manufacturers, suppliers, factory, generator sets, Portable Bio Gas Generator, gas generator sets, Portable LPG Generators, Bio Gas Generator System, Natural Gas Generators For Home