Large-Sized Diesel Generators

Large-Sized Diesel Generators

Sunrise's large diesel generator is equipped with a military grade powertrain, suitable for heavy-duty power supply needs in large scenarios. It combines ultra stable output, intelligent control, and low consumption environmental protection characteristics, laying a solid foundation for large-scale production and emergency support.
Send Inquiry
Chat Now
Description

Sunrise Large Diesel Generator (300-1000KVA) is a highly reliable power supply equipment designed for heavy-duty scenarios such as large industrial plants, data centers, urban emergency power supply, new energy power generation bases, mining and metallurgy. It can be used as the main power source to ensure large-scale continuous production, or as a backup power source to cope with regional power outages and sudden power supply failures. It balances heavy-duty output stability, long-term operation durability, and intelligent operation and maintenance convenience, and is suitable for extreme working conditions and high standard power supply needs.

 

Product Parameter

 

Product Model

SR-L400

SR-L700

SR-L900

Rated power (KVA)

four hundred

seven hundred

nine hundred

Backup power (KVA)

four hundred and forty

seven hundred and seventy

nine hundred and ninety

Rated voltage (V)

380/400/415 three-phase four wire

380/400/415 three-phase four wire

380/400/415 three-phase four wire (customizable high voltage)

Rated frequency (Hz)

50/60 (switchable)

50/60 (switchable)

50/60 (switchable)

Engine brand/model

Yuchai YC6K500L-D20

Cummins KTA19-G8

Weichai WP13G550E310

Fuel consumption (g/kw. h)

≤210

≤215

≤220

Noise (dB/A)

82-85

85-88

88-92 (customizable mute to within 75dB)

Dimensions (L × W × H mm)

4500×1600×2200

5200×1800×2500

6000×2000×2800

Weight (kg)

four thousand and eight hundred

six thousand and five hundred

eight thousand and two hundred

Startup method

Electric start/automatic start

Electric start/automatic start/remote start

Electric start/automatic start/remote start/cluster start

cooling method

Forced water cooling+fan cooling

Forced water cooling+industrial grade radiator

Forced water cooling+intelligent temperature control cooling system

 

1.Fuel consumption ≤ 210-220g/kw. h: Adopting high-pressure common rail+electronic injection technology, combined with intelligent load regulation system, the optimal fuel consumption is achieved under 60% -80% heavy load conditions, which is 4% -6% lower than similar products in the industry. Long term heavy load operation can significantly save fuel costs.

2. Noise level of 82-92dB/A: comes standard with industrial grade soundproof enclosures, multi-stage mufflers, and shock-absorbing bases. The basic noise level meets industrial scene standards; Customizable mute upgrade solution, by optimizing the sound insulation structure and heat dissipation layout, the noise can be reduced to within 75dB, suitable for indoor scenes with high noise requirements (such as data centers and urban emergency centers).

2.Cluster startup/parallel operation: Supports parallel operation of multiple units, with a maximum capacity of 4 1000KVA units for collaborative power supply, with a total power of 4000KVA; Capable of cluster startup and load balancing distribution, adapting to dynamic power demand in large scenarios, ensuring power supply stability

 

Product feature and application

 

Key Features of Our Largr-Sized diesel generator

Equipped with well-known brand engines such as Cummins K series and Weichai WP13 series:

The core components have undergone 2000 hours of continuous heavy load testing, with a failure rate of less than 0.3% and a service life of over 20000 hours, far exceeding the industry average level of large units, and suitable for long-term heavy load operation needs.

Heavy load adaptability:

The all copper winding generator paired with a reinforced powertrain can easily withstand an instantaneous 50% overload impact, with voltage and frequency accuracy controlled within ± 0.5%. It can stably drive heavy-duty equipment such as large compressors, water pumps, and production line clusters without the risk of shutdown.

Intelligent cluster control:

Equipped with an industrial grade PLC intelligent control system, it supports parallel operation of multiple units and remote cluster control (computer/mobile end), real-time monitoring of 20+operating parameters, with fault prediction, automatic alarm and remote diagnosis functions. It can predict potential faults 72 hours in advance and reduce downtime losses.

Adaptation under extreme conditions:

High-strength steel structure body with protection level up to IP55 can withstand extreme conditions such as high temperature (-30 ℃~55 ℃), high humidity, dusty, rainstorm, etc; Standard winter preheating system, can start normally in -30 ℃ environment, suitable for cold regions and outdoor heavy load scenarios.

11001
12001
13001
14001
15001
16001
17001

18

19

 

It can be used in various scenarios.

1. Large industrial scenarios: Suitable for large refineries, metallurgical mines, automobile manufacturing plants, heavy machinery factories, etc., as the main power source to ensure the continuous operation of production line clusters and large equipment, or as a backup power source to cope with sudden power outages and avoid huge production losses caused by power outages; Core advantages: Heavy load stable supply, long-term operation, low failure.

2. Data center scenario: Suitable for large cloud computing data centers, IDC rooms, etc., as a backup power source to ensure the continuous operation of server clusters and cooling systems, requiring zero power outage switching; Core advantages: intelligent control, zero latency startup, low noise, cluster operation.

3. Urban emergency scenarios: Suitable for urban emergency power supply centers, hospital headquarters, transportation hubs (airports/high-speed railway stations), etc., as emergency power sources to ensure the power supply of people's livelihoods and public service facilities; Core advantages: adaptation to extreme working conditions, long endurance, fast start, intelligent unmanned operation.

4. New energy base scenario: Suitable for photovoltaic power stations, wind power bases, energy storage power stations, etc., serving as peak shaving power sources and backup power sources, balancing fluctuations in new energy generation, and ensuring grid stability; Core advantages: parallel operation, load regulation, environmental protection and low consumption, long-term endurance.

 

367001

 

Production details

 

Engine: First tier brand original, cylinder body made of high-strength cast iron material, resistant to high temperature and wear;

Generator: All copper winding, good conductivity, high efficiency, strong voltage stability;

Control system: LCD high-definition display screen, simple operation, protection level IP54, dustproof and waterproof.

Body frame: welded with steel sections, with a sturdy structure and strong load-bearing capacity;

Surface treatment: electrostatic spraying process, corrosion-resistant, rust proof, suitable for outdoor humid and dusty scenes;

Each unit undergoes strict testing before leaving the factory, including 18 testing items such as 200 hours of heavy-duty operation test, no-load test, load impact test, noise test, environmental protection test, and low-temperature start-up test. Only after passing the testing can it be shipped to ensure that each product meets the high standard quality requirements of large-scale scenarios.

 

408

21001
22001
23001

24

 

Product Certification

 

The Sunrise power Medium-Sized diesel generator set strictly follows international and domestic power equipment and noise standards. After multiple authoritative tests, the quality, safety, and noise reduction effect are double guaranteed, and can be safely used in various noise sensitive scenarios

405

 

FAQ

 

Q: Do large units require regular maintenance? What is the maintenance cycle and cost?

A: Regular maintenance is required, and it is recommended to perform routine maintenance every 800 hours of operation (changing oil, filter element, checking coolant, cleaning radiator); Maintenance consumables have strong universality and controllable procurement costs. The cost of a regular maintenance is about 1500-3000 yuan (depending on the size of the model). We can provide regular on-site maintenance services or train your personnel to operate them on their own.

Q: Can the unit operate normally in extreme environments such as high and low temperatures?

A: It can operate normally, with a protection level of IP55 for the unit, and is suitable for environmental temperatures ranging from -30 ℃ to 55 ℃; The default configuration includes a winter preheating system and a summer intelligent cooling system, which can quickly start at -30 ℃ and run stably at 55 ℃; For extreme sandstorm and rainstorm scenarios, additional protection upgrading schemes can be customized.

Q: What is the required starting power for a large unit? Does it support automatic start and zero power switch?

A: Equipped with a large capacity starter battery as standard, no additional starter power supply is required; Supports automatic startup within 3 seconds after power failure and automatic shutdown within 5 seconds after power restoration, achieving zero power outage switching and adapting to scenarios such as data centers and hospitals with zero tolerance for power outages.

 

Packing & Shipping

 

421

411

 

Hot Tags: large-sized diesel generators, China large-sized diesel generators manufacturers, suppliers, factory, Portable Diesel Generator, Silent Type Diesel Generator, Perkins Diesel Generator, Large Sized Diesel Generators, Medium Sized Diesel Generators, Catapillar Diesel Generator