When the mains supply is normal, the product can output the mains supply directly; meanwhile it charges the accumulator through the charger; when the mains supply goes wrong or is interrupted or lower than the set limit, its built-in inverter system will start to work automatically to invert the DC stored in its accumulator into the stable AC power supply to continue power supply for the load to ensure the need for emergency power supply.
electrical performance parameters(STC)
|
Protection grade |
IP65 |
|
Product Name |
Outdoor fire power supply EPS cabinet |
|
External dimensions |
1900*600*410 |
|
Material |
Galvanized sheet/stainless steel/cold plate |
|
Maintenance method |
Front double door, floor mounted installation |
|
Heat dissipation method |
Breathable hole+fan combination |
|
Color |
Available in color, gray, silver, or Customize Color |
|
Certification |
CE/RoHS,IP Test Certificate |
|
Custom Design |
Yes |
|
Sample Lead Time |
15-25 Days |
|
OEM,ODM |
OEM/ODM |
Application field
Power supply and fire protection for various types of buildings: hospitals, city squares, theaters, commercial buildings
Industrial system: Fire power supply
Transportation system: highways, tunnels, subways, light rails, civil airports
Other types of primary and particularly important loads




The working principle of EPS
1. When the mains power is normal, it supplies power to important loads through the interconnection device, while conducting mains power detection and battery charging management. Then, the battery pack provides DC energy to the inverter. Here, the charger is a low-power DC power supply that only needs to provide a charging current equivalent to 10% of the battery capacity (Ah) to the battery pack, and it does not have the ability to directly provide DC power to the inverter. At this time, the mains power supplies various emergency loads to users through the power supply system composed of EPS AC bypass and transfer switch. At the same time, under the control of the EPS logic control board, the inverter stops working and is in an automatic shutdown state. Under these conditions, the actual power source used by the user load is the mains power from the power grid. Therefore, EPS emergency power supply is also commonly referred to as always working in a sleep state, which can effectively achieve energy-saving effects.
2. When the mains power supply is interrupted or the mains voltage exceeds the rated input voltage (± 15% or ± 20%), the interconnection device will immediately switch to the inverter power supply. With the support of the DC energy provided by the battery pack, the power source used by the user load is the AC power converted by the EPS inverter, not from the mains power.
3. When the mains voltage returns to normal operation, the control center of EPS sends a signal to perform automatic shutdown operation on the inverter, and also switches from inverter power supply to AC bypass power supply through its transfer switch. Afterwards, EPS provides mains power to the load through the AC bypass power supply path and also charges the battery pack through a charger.
4. In addition to being used in emergency lighting systems, the three-phase intelligent variable frequency emergency power supply mainly provides a variable frequency emergency power supply system for the electric motor in the first level load. This product conveniently solves the impact of emergency power supply for the electric motor and its starting process on the power supply equipment. The intelligent emergency power supply can accept fire linkage signals and building intelligent bus signal control, and can set priorities to prevent leapfrog control.





Maintenance and precautions of EPS
Regular maintenance and inspection are essential to ensure the reliable operation of the EPS system at critical moments. Here are some precautions for maintaining and using EPS:
Regularly check the status of the battery pack to ensure that it is fully charged and undamaged.
Check if the charger is working properly to avoid overcharging or undercharging.
Regularly conduct load tests to ensure that the EPS system can function properly under actual loads.
Check the functionality of the static switch and control system to ensure accurate power switching.
Follow the manufacturer's maintenance guidelines and conduct regular professional maintenance and inspections.
FAQ
Q: What is the emergency power supply endurance time of EPS? Does it support customization?
A: The standard configuration has a battery life of 90 minutes (meeting the core requirements of fire emergency), and also supports on-demand customization (30 minutes -8 hours optional); The battery life can be achieved by adjusting the battery capacity. If longer battery life is required, it can be extended with an external battery pack to meet the long-term backup needs of special scenarios such as data centers and hospital intensive care units.
Q: What is the switching time for EPS emergency power supply? Can sensitive equipment requirements be met?
A: The switching time for conventional models is ≤ 0.2 seconds, fully meeting the seamless switching requirements for loads such as fire equipment, lighting, elevators, etc; For scenarios with higher switching time requirements such as precision instruments and servers, customized millisecond level (≤ 10ms) switching options can be provided to avoid equipment downtime or data loss.
Q: Is it difficult to install EPS products? Do you need professional personnel to operate?
A: The installation process is simple, supporting wall mounted and floor standing installations (small models can be wall mounted, high-power models require floor standing fixation), without the need for complex on-site circuit modifications; However, due to the involvement of electrical wiring and fire linkage debugging, it is recommended to have professional personnel with electrician qualifications install it. We can provide installation guidance manuals, video tutorials, or coordinate with local cooperative engineers for on-site debugging.
Q: What should be noted for the daily maintenance of EPS emergency power supply? Is the maintenance cost high?
A: Daily maintenance is simple, with three key points to note: ① Keep the equipment ventilated and dry, avoiding dust and humid environments; ② Perform an emergency start test once a month using the panel test button (duration 5-10 minutes); ③ Conduct battery performance testing and host dust removal once a year; Low maintenance cost, core consumables are batteries (with a lifespan of 3-5 years), supporting individual replacement without the need for overall equipment replacement.
Packing & Shipping



Hot Tags: emergency power supplies eps, China emergency power supplies eps manufacturers, suppliers, factory, power energy storage and emergency equipment, Emergency Indicator Lights, Backup Power Distribution Boxes, Uninterruptible Power Supplies UPS System, Emergency Spotlight, emergency systems